Home>Products

Magnetostrictive Displacement Sensor

Kingmach Magnetostrictive Displacement Sensor include the JMCW-21XXADT Magnetostrictive Displacement Meter for absolute linear position measurement. This sensor uses magnetostrictive effect and internal non-contact sensing, which avoids mechanical wear and supports continuous operation in harsh environments. Product information lists 0 to 1000 mm measuring range, 0.01 mm resolution, plus or minus 0.05%FS accuracy, repeatability within 0.1 mm, DC24V plus or minus 10% input, RS485 communication, average operating current below 60 mA, and an operating temperature range from -30 degrees Celsius to +80 degrees Celsius. It also lists IP67 protection and reverse polarity protection up to -36V. Wiring details include red for DC24V, yellow for power ground, blue for RS485A, and green for RS485B. These features make the product suitable for hydraulic cylinders, gate position, machine stroke, structural deformation, railway and highway movement, retaining walls, and industrial automation equipment that requires stable absolute position data. During project setup, the measuring point should be matched with the expected travel direction, available mounting space, cable route, and required acquisition interval. This prevents a short-range joint instrument from being used on a long-travel point, or an exposed sensor from being placed where an embedded anchor is needed. It also helps the monitoring team set a baseline that can be defended during acceptance and later maintenance review.

Application of  Magnetostrictive Displacement Sensor

Application of Magnetostrictive Displacement Sensor

In bridge monitoring, Magnetostrictive Displacement Sensor are used at expansion joints, bearing zones, abutments, arch supports, deck gaps, and structural interfaces where relative movement affects service safety. The common pain point is that bridge movement may look normal during one inspection but reveal risk when compared over temperature cycles, traffic load, and maintenance events. Kingmach JMDL-52XXADT differential meters cover 20 mm, 50 mm, and 100 mm ranges with 0.01 mm resolution, plus or minus 0.1%FS accuracy, RS485 output, and low temperature drift. JMDL-22XXAT crack gauges can track joint opening or crack width up to 200 mm, while JMLS-22XXADT wire rope sensors can monitor longer movement paths up to 2000 mm. When displacement readings are paired with strain gauges, load cells, tiltmeters, and weather data, bridge teams can distinguish seasonal joint travel from abnormal movement, bearing restraint, foundation settlement, or localized damage. During operation, the monitoring team should keep the baseline, temperature, inspection notes, and nearby sensor behavior in the same review file. This makes it easier to tell whether a movement trend comes from normal service, a repair event, changing load, water influence, or developing structural risk. Clear records also help owners decide when a field inspection is needed instead of waiting for visible damage.

The future of Magnetostrictive Displacement Sensor

The future of Magnetostrictive Displacement Sensor

Future Magnetostrictive Displacement Sensor will likely place more intelligence at the edge of the monitoring network. Instead of sending every reading to a platform without review, acquisition units can check whether a displacement jump is physically plausible, whether the temperature moved at the same time, and whether nearby channels changed in the same direction. Kingmach smart products already store measurement time, temperature for temperature versions, absolute displacement, relative displacement, and zero-point values on selected models. That local record can support early filtering and field diagnosis. For remote slopes, dams, subgrades, and tunnel portals, this matters because network access may be unstable and maintenance visits may be expensive. Edge checks can flag cable damage, zero drift, sudden water ingress, or installation movement before the data is accepted as structural deformation. The strongest systems will still depend on careful installation, because digital tools cannot correct a loose bracket, wrong range, or poorly recorded baseline. Clear reporting will make displacement monitoring more useful for non-specialist decision makers while preserving the detail engineers need.

Care & Maintenance of Magnetostrictive Displacement Sensor

Care & Maintenance of Magnetostrictive Displacement Sensor

For formwork and construction-stage Magnetostrictive Displacement Sensor, inspection frequency should match the work rhythm. Kingmach JMDL-49XXAT formwork displacement meters may be used during concrete pouring, steel pipe support monitoring, tunnel portal movement, slope sliding, dam displacement, or railway subgrade monitoring. The product lists IP68 protection, 0.01 mm sensitivity, 0.5%FS accuracy, and a 30-year service life, but construction sites can still damage connectors, brackets, and cables quickly. Before pouring, confirm the zero reading, bracket tightness, cable route, warning level, and acquisition interval. During pouring or loading, watch for sudden jumps that match pump movement, support adjustment, or worker contact. After the stage is complete, inspect whether the sensor was knocked, buried, or moved. Keep time and temperature records with displacement readings because short-term construction movement can be different from long-term structural deformation. Keep the installation photo, point number, zero value, and expected movement direction with the commissioning record for later review. If a reading changes after maintenance work, inspect the base, anchor, cable, and cabinet before assuming the structure itself has moved.

Kingmach Magnetostrictive Displacement Sensor

Long-term projects need Magnetostrictive Displacement Sensor that can survive the same weather, vibration, cable pulling, and site handling as the structure itself. Kingmach designs several smart displacement products with built-in memory chips, digital detection, strong anti-interference capability, and direct display through compatible testers. The JMDL-22XXAT crack gauge stores up to 600 measurement results and covers 20 mm, 50 mm, 100 mm, and 200 mm models. The JMDL-21XXAT general-purpose model stores up to 800 records and can save time, temperature, absolute displacement, relative displacement, and zero-point values. These records matter during handover because the original baseline, later shifts, and abnormal readings can be checked without relying only on handwritten notes. For bridges, dams, tunnels, slopes, and buildings, that traceability helps maintenance teams judge whether a movement event is isolated, repeated, or linked with surrounding construction and environmental change. The point should be named on the drawing, linked with its cable route, and checked against the expected movement direction before the first automatic reading is accepted. For daily review, the reading should be compared with nearby points, recent weather, site operations, and any loading event that could explain the movement.

FAQ

  • Q: Which Magnetostrictive Displacement Sensor are used for rock layers or bedrock?
    A: JMDL-31XXAT multipoint meters are used for different surrounding rock layers, while JMDL-32XXAT single-point bedrock meters are used for tunnel rock mass, dam bedrock, slope, or foundation pit movement.

    Q: How many points can the multipoint meter support?
    A: The multipoint installation kit supports three to five monitoring points, with anchor heads fixed at different depths by drilling and grouting.

    Q: What ranges are listed for these models?
    A: Both JMDL-31XXAT and JMDL-32XXAT list 50 mm, 100 mm, and 200 mm models with 0.01 mm resolution.

    Q: Why monitor several depths?
    A: Different layers may move differently. Separating shallow and deep movement helps engineers judge whether the problem is surface creep, deeper rock slip, or overall mass movement.

    Q: What records should be kept?
    A: Keep drilling depth, anchor location, grouting date, channel name, zero value, cable route, and first stable reading.

Reviews

James Thompson

The tiltmeters and accelerometers are very sensitive and provide precise data. Perfect for our structural health monitoring system.

Daniel Brown

Excellent environmental monitoring sensors. The data is consistent, and the system integrates smoothly with our existing setup.

Latest Inquiries

To protect the privacy of our buyers, only public service email domains like Gmail, Yahoo, and MSN will be displayed. Additionally, only a limited portion of the inquiry content will be shown.

Harper***@gmail.comIndia

Dear Sir, we are planning to procure a complete monitoring system including strain gauges, tiltmeter...

Emma***@gmail.comCanada

Dear Sir/Madam, we are interested in displacement transducers and settlement sensors for a geotechni...

Not finding what you're looking for?
Contact our consultants for more available products.

Request A Quote Now

GET IN TOUCH

If you are interested in our products or want to become our partner.

Please leave your contact information, our team will contact you as soon as possible.

Contact Us Now
Copyright © Kingmach Measurement & Monitoring Technology Co., Ltd.
get a quote
Your Name:
E-mail:*
Company:
Phone/WhatsApp:
Content: